{"id":2264,"date":"2022-06-20T11:34:54","date_gmt":"2022-06-20T17:34:54","guid":{"rendered":"https:\/\/astfilters.com\/wastewater\/?page_id=2264"},"modified":"2026-10-19T11:33:32","modified_gmt":"2026-10-19T17:33:32","slug":"bod-cod-removal","status":"publish","type":"page","link":"https:\/\/astfilters.com\/wastewater\/filter-applications\/bod-cod-removal\/","title":{"rendered":"BOD \/ COD Removal"},"content":{"rendered":"\n<div class=\"et_pb_section_0 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_0 et_pb_row et_block_row\"><div class=\"et_pb_column_0 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"lwp-breadcrumbs_0 lwp-breadcrumbs et_pb_bg_layout_light et_pb_module\"><div class=\"et_pb_module_inner\"><div class=\"lwp-breadcrumbs\"><span class=\"before\"><\/span> <span vocab=\"https:\/\/schema.org\/\" typeof=\"BreadcrumbList\"><span property=\"itemListElement\" typeof=\"ListItem\"><a property=\"item\" typeof=\"WebPage\" href=\"https:\/\/astfilters.com\/wastewater\/\" class=\"home\"><span property=\"name\">Home<\/span><\/a><meta property=\"position\" content=\"1\"><\/span> <span class=\"separator et-pb-icon\">E<\/span> <\/span><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"et_pb_section_1 et_pb_section et_pb_fullwidth_section et_section_regular et_block_section\"><section class=\"et_pb_fullwidth_header_0 et_pb_fullwidth_header et_pb_bg_layout_dark et_pb_text_align_left et_pb_module et_flex_module\"><div class=\"et_pb_fullwidth_header_container left\"><div class=\"header-content-container center\"><div class=\"header-content et_flex_module\"><div class=\"et_pb_header_button_wrapper\"><\/div><\/div><\/div><\/div><div class=\"et_pb_fullwidth_header_overlay\"><\/div><div class=\"et_pb_fullwidth_header_scroll\"><\/div><\/section><\/div><div class=\"et_pb_section_2 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_1 et_pb_row et_block_row eightypercent_row\"><div class=\"et_pb_column_1 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_0 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><h1>Wastewater BOD \/ COD Removal<\/h1>\n<\/div><\/div><\/div><\/div><div class=\"et_pb_row_2 et_pb_row et_pb_row_3-4_1-4 et_block_row et_block_row_3-4_1-4 eightypercent_row\"><div class=\"et_pb_column_2 et_pb_column et_pb_column_3_4 et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_1 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><p>COD is composed of readily biodegradable BOD and refractory organics that resist bacterial attack. With a floating bead media filter, COD reduction is accomplished through the extraction of organic particulate matter (TSS removal) and bacterial oxidation of biodegradable dissolved organics (BOD removal). AST\u2019s bead filters can carry out aerobic BOD removal through the filter's biological activity or direct removal of particulate organics. Refractory organics can be pretreated with ozone to allow the bead filter to remove molecular fragments and precipitates that may have formed in the ozonation process.<\/p>\n<\/div><\/div><div class=\"et_pb_module et_pb_button_module_wrapper et_pb_button_0_wrapper\"><a class=\"et_pb_button_0 et_pb_button et_pb_bg_layout_light et_pb_module et_block_module green_button\" href=\"\/wastewater\/filter-equipment\/\"><span class=\"et-pb-parallax-content\">Learn About Filters<\/span><\/a><\/div><div class=\"et_pb_text_2 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><p>With over 20 years of experience, we\u2019ve installed our specialized wastewater treatment systems in a wide variety of settings and applications. Groundwater remediation, industrial wastewater, domestic wastewater, agricultural wastewater, and more \u2013 no matter the application we can help you eliminate wastewater fines and surcharges.<\/p>\n<\/div><\/div><div class=\"et_pb_module et_pb_button_module_wrapper et_pb_button_1_wrapper\"><a class=\"et_pb_button_1 et_pb_button et_pb_bg_layout_light et_pb_module et_block_module green_button\" href=\"\/wastewater\/request-a-quote\/\"><span class=\"et-pb-parallax-content\">Request a No Cost Consultation<\/span><\/a><\/div><\/div><div class=\"et_pb_column_3 et_pb_column et_pb_column_1_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_image_0 et_pb_image et_pb_module et_block_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/astfilters.com\/wastewater\/wp-content\/uploads\/sites\/2\/2017\/06\/Acclimated-beads.jpg\" width=\"400\" height=\"711\" srcset=\"https:\/\/astfilters.com\/wastewater\/wp-content\/uploads\/sites\/2\/2017\/06\/Acclimated-beads.jpg 400w, https:\/\/astfilters.com\/wastewater\/wp-content\/uploads\/sites\/2\/2017\/06\/Acclimated-beads-169x300.jpg 169w\" sizes=\"(max-width: 400px) 100vw, 400px\" class=\"wp-image-1147\" title=\"Acclimated-beads\" \/><\/span><\/div><div class=\"et_pb_text_3 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><p style=\"text-align: center\"><i>Acclimated Beads<\/i><\/p>\n<\/div><\/div><\/div><\/div><div class=\"et_pb_row_3 et_pb_row et_block_row eightypercent_row\"><div class=\"et_pb_column_4 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_4 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><h3>Bead Filters as Biological Filters<\/h3>\n<p>A floating bead media filter acts as a fixed film reactor with bacteria growing on the surface of the beads in a layer that is a hundreds of microns thick. If biological activity is desired, the filter must be managed to encourage the culture of heterotrophic bacteria. Typical control issues include flowrate, substrate concentration, oxygen supply, backflush frequency, temperature, and pH. Fortunately, development of a heterotrophic fixed film is a natural process easily accomplished in an expandable granular format. All PolyGeysers used as biological filters should employ EN media which displays a better porosity and provides protection for the biofilm during high frequency\u00a0backwashing events. The units display a high specific surface area for biofilm development in the range of 1100-1200 m<sup>2<\/sup>\/m<sup>3<\/sup>.<\/p>\n<h3>Frequent Backwashing Prevents Biofouling<\/h3>\n<p>Bead filters can be operated in a wide variety of BOD concentration regimes. The PolyGeyser units are virtually impervious to biofouling, and with a high backwashing frequency, they can be effectively used as roughing filters reducing particulate BOD of raw wastes with high BOD and TSS concentrations. Roughing filters are managed with a high frequency of backwashing (down to about once an hour) to prevent clogging of the bed. Peak conversions on waste streams with CBOD<sub>5<\/sub> levels below 100 mg\/L typically fall in the 3-6 hour backwash interval range. Rapidly growing biofilms uptake dissolved organics producing biomass that is then removed before the demand can be fully expressed reducing oxygen demand.<\/p>\n<h3>CBOD Conversion Rates<\/h3>\n<p>Conversion rates for CBOD are measured in units of kilograms per cubic meter of beads per day (kg\/m<sup>3<\/sup>-day). In general, the removal rate is controlled by the CBOD loading rate (kg-CBOD<sub>5<\/sub>\/m<sup>3<\/sup>-day). For CBOD effluent qualities below about 30 mg\/L the conversion rate is proportional to the effluent concentration. For example, for a domestic waste source, the unit\u2019s removal rate has been observed to be 2 kg\/m<sup>3<\/sup>-day at a target effluent concentration of 10 mg-CBOD<sub>5<\/sub>\/L. At higher CBOD concentrations the removal relation tends to increase exponentially probably reflecting the increasing proportion of the CBOD<sub>5\u00a0<\/sub>that is associated with particulates. Removal of organic particulates greater than 30 microns is rapid. No biological activity is required, just capture and remove. Insight into the potential removal rate for any application is gained by analyzing a sample for soluble and particulate CBOD.<\/p>\n<h3>Recirculating Filtration<\/h3>\n<p>Most CBOD removal problems are addressed with filters configured to recycle water multiple times through a PolyGeyser. The need for recirculation is largely driven by the need to supply oxygen to the submerged bed. Recirculation also facilitates a longer contact time with the bacteria-laden bead media. Water is in contact for only about 20 seconds in a single pass through the bed. During this 20 seconds, a heavily loaded filter will consume most of the oxygen in the water dropping the concentration from around 5 mg\/l to below 1 mg\/l. Recirculating the water repeatedly through the bed can increase the oxygen supply to the 6-10 kg\/m<sup>3<\/sup>-day range demanded by a heavily loaded filter. CBOD removal rates are typically 2-3 times the heterotrophic oxygen consumption rates. Recirculation rates are normally set at 10 gpm\/ft<sup>3<\/sup> but can be reduced to conserve energy whenever oxygen demands allow.<\/p>\n<p>The <a href=\"https:\/\/astfilters.com\/wastewater\/filter-equipment\/recirculating-polygeyser-filter\/\">RCPG series<\/a> has a recirculation tank built into the unit to facilitate recirculation. The units employ energy efficiency using airlifts to recirculate and aerate simultaneously in a low head (typically 4-6 inches) recirculation. The <a href=\"https:\/\/astfilters.com\/wastewater\/filter-equipment\/high-profile-polygeyser-filter\/\">HPPG series<\/a> can be configured with a packed tower for an adjoining tank, however, lifts are of the order of 10-15 feet. <a href=\"https:\/\/astfilters.com\/wastewater\/filter-equipment\/low-profile-polygeyser-filter\/\">LPPG units<\/a> can be configured with airlifts and a matching tank at the same elevation. These units are ideal for treatment of organically rich waters that are relatively free of fixed suspended solids.<\/p>\n<p>Total BOD (TBOD20\u00a0or TBOD<sub>5<\/sub>) will be impacted by the particulate removal, by the heterotrophic action on dissolved organics, and by removal of ammonia\/nitrite by nitrifying bacteria. Carbonaceous BOD (CBOD20\u00a0or CBOD<sub>5<\/sub>) is impacted by the particulate and dissolved organic removal, but not the nitrifiers as their activity is suppressed in the CBOD test. All bead filters nitrify even at high organic loadings as long as oxygen is present in the bed. It must be presumed that a nitrifier seed is available in any effluent sample collected, thus inhibition (CBOD) is required to get an accurate assessment of organic reduction. This is particularly important when attempting to comply with stringent effluent standards.<\/p>\n<h3>Concentrating Biosolids<\/h3>\n<p>Sludge production and handling is an issue anytime an aerobic process is used for BOD reduction as approximately 0.6 kg of biofilm is produced per kg of BOD removed (kg\/kg). As part of their backwash cycle, PolyGeyser units shed, settle, and concentrate biosolids produced by the BOD conversion process. When a high-frequency backwashing is employed biodegradation of the biosolids (sludge) is minimized and perhaps 0.5 kg\/kg of solids must be removed from the filter. Assuming a sludge concentration of 1% (10,000 mg-TSS\/l), about 50 liters (13 gallons) of sludge is produced for every kg of BOD that is removed. For this reason, PolyGeysers designed for heavy BOD removal loads should be equipped with automated or pneumatic sludge removal. A means of the handling, treating and disposing of the sludge should be provided. Common practice is to discharge the sludge to an upstream clarifier.<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"et_pb_section_3 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_4 et_pb_row et_block_row eightypercent_row\"><div class=\"et_pb_column_5 et_pb_column et_pb_column_2_5 et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_image_1 et_pb_image et_pb_module et_block_module\"><a href=\"\/wastewater\/case-study-lagoon-polishing-pelahatchie-mississippi\/\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/astfilters.com\/wastewater\/wp-content\/uploads\/sites\/2\/2016\/07\/RCPG-lagoon-treatment.jpg\" width=\"1000\" height=\"757\" srcset=\"https:\/\/astfilters.com\/wastewater\/wp-content\/uploads\/sites\/2\/2016\/07\/RCPG-lagoon-treatment.jpg 1000w, https:\/\/astfilters.com\/wastewater\/wp-content\/uploads\/sites\/2\/2016\/07\/RCPG-lagoon-treatment-980x742.jpg 980w, https:\/\/astfilters.com\/wastewater\/wp-content\/uploads\/sites\/2\/2016\/07\/RCPG-lagoon-treatment-480x363.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1000px, 100vw\" class=\"wp-image-1161\" title=\"RCPG-lagoon-treatment\" \/><\/span><\/a><\/div><\/div><div class=\"et_pb_column_6 et_pb_column et_pb_column_3_5 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_5 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><h2>See Our Recent Case Study<\/h2>\n<h4>Pilot RCPG System for Facultative Lagoon Polishing<\/h4>\n<p>In order to meet increasingly strict discharge standards, AST provided a trailer mounted pilot scale test unit to pull a side stream off of the current waste stream.<\/p>\n<\/div><\/div><div class=\"et_pb_module et_pb_button_module_wrapper et_pb_button_2_wrapper\"><a class=\"et_pb_button_2 et_pb_button et_pb_bg_layout_light et_pb_module et_block_module\" href=\"\/wastewater\/case-study-lagoon-polishing-pelahatchie-mississippi\/\"><span class=\"et-pb-parallax-content\">Read Case Study<\/span><\/a><\/div><\/div><\/div><\/div><div class=\"et_pb_section_4 et_pb_section et_section_regular et_block_section\"><div class=\"et_pb_row_5 et_pb_row et_block_row\"><div class=\"et_pb_column_7 et_pb_column et_pb_column_4_4 et-last-child et_block_column et_pb_css_mix_blend_mode_passthrough\"><div class=\"et_pb_text_6 et_pb_text et_pb_bg_layout_light et_pb_module et_block_module\"><div class=\"et_pb_text_inner\"><h2 style=\"text-align: center\">Let's Discuss Your Project<\/h2>\n<p style=\"text-align: center;margin-top: 35px\">From a simple filter to a complete custom system, our engineers can help you find the perfect filtration system for your needs. Get in touch today!<\/p>\n<\/div><\/div><div class=\"et_pb_module et_pb_button_module_wrapper et_pb_button_3_wrapper\"><a class=\"et_pb_button_3 et_pb_button et_pb_bg_layout_light et_pb_module et_block_module\" href=\"\/wastewater\/request-a-quote\/\" data-icon=\"5\"><span class=\"et-pb-parallax-content\">Request a No Cost Consultation<\/span><\/a><\/div><\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":8,"featured_media":0,"parent":616,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"class_list":["post-2264","page","type-page","status-publish","hentry"],"acf":[],"dsm_author":{"name":"kevinudydigital","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/8f0e9dacd9c218b6f98ec32948c213e768a85e365726b5b9a98620d730cc1739?s=96&d=mm&r=g","archive_link":"https:\/\/astfilters.com\/wastewater\/blog\/author\/kevinudydigital\/","biodata":""},"dsm_categories":[],"dsm_attachment_categories":[],"dsm_featured_image":null,"dsm_comment_count":0,"_links":{"self":[{"href":"https:\/\/astfilters.com\/wastewater\/wp-json\/wp\/v2\/pages\/2264","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/astfilters.com\/wastewater\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/astfilters.com\/wastewater\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/astfilters.com\/wastewater\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/astfilters.com\/wastewater\/wp-json\/wp\/v2\/comments?post=2264"}],"version-history":[{"count":1,"href":"https:\/\/astfilters.com\/wastewater\/wp-json\/wp\/v2\/pages\/2264\/revisions"}],"predecessor-version":[{"id":6991,"href":"https:\/\/astfilters.com\/wastewater\/wp-json\/wp\/v2\/pages\/2264\/revisions\/6991"}],"up":[{"embeddable":true,"href":"https:\/\/astfilters.com\/wastewater\/wp-json\/wp\/v2\/pages\/616"}],"wp:attachment":[{"href":"https:\/\/astfilters.com\/wastewater\/wp-json\/wp\/v2\/media?parent=2264"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}