{"id":3211,"date":"2016-08-26T10:31:04","date_gmt":"2016-08-26T16:31:04","guid":{"rendered":"https:\/\/astfilters.com\/?page_id=3211"},"modified":"2024-02-08T10:25:19","modified_gmt":"2024-02-08T17:25:19","slug":"high-profile-polygeyser-faq-troubleshooting","status":"publish","type":"page","link":"https:\/\/astfilters.com\/aquatic-systems\/support\/high-profile-polygeyser-filter-resources\/high-profile-polygeyser-faq-troubleshooting\/","title":{"rendered":"High Profile PolyGeyser FAQ &#038; Troubleshooting"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; admin_label=&#8221;Breadcrumbs&#8221; _builder_version=&#8221;4.21.0&#8243; _module_preset=&#8221;default&#8221; background_color=&#8221;#363636&#8243; custom_margin=&#8221;10px||0px||false|false&#8221; custom_padding=&#8221;0px||0px||false|false&#8221; saved_tabs=&#8221;all&#8221; global_colors_info=&#8221;{}&#8221; global_module=&#8221;2946&#8243; theme_builder_area=&#8221;post_content&#8221;][et_pb_row _builder_version=&#8221;4.18.0&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;15px||15px||false|false&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;4.18.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][lwp_divi_breadcrumbs font_icon=&#8221;&#x45;||divi||400&#8243; link_color=&#8221;#ffffff&#8221; separator_color=&#8221;#ffffff&#8221; current_text_color=&#8221;#ffffff&#8221; _builder_version=&#8221;4.18.0&#8243; _module_preset=&#8221;default&#8221; global_colors_info=&#8221;{}&#8221; theme_builder_area=&#8221;post_content&#8221;][\/lwp_divi_breadcrumbs][\/et_pb_column][\/et_pb_row][\/et_pb_section][et_pb_section fb_built=&#8221;1&#8243; theme_builder_area=&#8221;post_content&#8221; _builder_version=&#8221;4.23.4&#8243; _module_preset=&#8221;default&#8221; custom_padding=&#8221;0px||||false|false&#8221; hover_enabled=&#8221;0&#8243; sticky_enabled=&#8221;0&#8243;][et_pb_row _builder_version=&#8221;4.23.4&#8243; _module_preset=&#8221;default&#8221; theme_builder_area=&#8221;post_content&#8221;][et_pb_column _builder_version=&#8221;4.23.4&#8243; _module_preset=&#8221;default&#8221; type=&#8221;4_4&#8243; theme_builder_area=&#8221;post_content&#8221;][et_pb_text _builder_version=&#8221;4.23.4&#8243; _module_preset=&#8221;default&#8221; theme_builder_area=&#8221;post_content&#8221; hover_enabled=&#8221;0&#8243; sticky_enabled=&#8221;0&#8243;]<\/p>\n<h1 style=\"text-align: center;\">High Profile PolyGeyser FAQ &amp; Troubleshooting<\/h1>\n<h4><strong>Dirty water comes out of my filter after a backwash.<\/strong><\/h4>\n<p>The\u00a0HPPG was specifically designed to minimize this issue.<\/p>\n<ol>\n<li>You are manually activating the backwash: The HPPG unit was designed with the presumption that backwash intervals would be short. Automate the unit and increase the backwash frequency<\/li>\n<li>You have the unit on an extended backwash interval: Increase the backwash frequency and keep the bed clean of debris.<\/li>\n<li>If your unit takes more than 5 seconds for air discharge: The trigger is blocked or partially blocked. You have a dysfunctional trigger and the unit is not dropping properly. See the section on the air \u201cburps\u201d.<\/li>\n<li>If your unit washes quickly (&lt;5 seconds) but fails to drop (look through the port hole), you may be flooding the filter with excessive flow during the wash. Check if your water pump sized properly for the HPPG model.<\/li>\n<\/ol>\n<p><strong>\u00a0<\/strong><\/p>\n<h4><strong>The flow coming out of my HPPG is dramatically reduced.\u00a0 <\/strong><\/h4>\n<p>Check your pressure gauge on the pump side of the filter. If it low, you have a water pump issue. If it is high, you have a backwash problem.<\/p>\n<ul>\n<li>If your pump pressure is normal or high then you have an air delivery problem and the bed is clogging.Check the rotary meter for the air. If the ball is down, open up the rotary meter and increase air flow to the charge chamber.\n<ul>\n<li>Ball will not come up. Your air pump cannot overcome the hull pressure established by the water pump. This is most commonly seen with linear air pumps.<\/li>\n<li>You may have just set your backwash interval too low and now you are trying to push against the shutoff pressure of the water pump.\n<ol>\n<li>Turn off the water pump and increase the backwash frequency. Let the unit dry wash for several cycles then turn the pump back on and set your backwash frequency higher.\n<ol>\n<li>Put a pressure relief valve on the intake side of the filter and set it below the shutoff pressure of your air pump.<\/li>\n<li>Buy an air compressor with a shut off pressure higher than your water pump.<\/li>\n<\/ol>\n<\/li>\n<li>Inspect the line between the rotary meter and the HHPG \u00a0 Is there a kink or has something pinched the line off?<\/li>\n<li>The diaphragm in my linear air pump is developing a crack.\n<ol>\n<li>Replace the diaphragm. At high pressures, the diaphragm in a linear air pump will fail in a year or two.<\/li>\n<\/ol>\n<\/li>\n<li>The ball comes up: Problem over, or\u2026\n<ol>\n<li>Check the line between the rotameter and the HPPG unit. Has the line slipped or is there an air leak where the line is connected to the HPPG unit?<\/li>\n<li>Has the external hull been damaged? Is there any evidence of a water leak on the bottom half of the unit?<\/li>\n<\/ol>\n<\/li>\n<li>If the pump pressure is low:\n<ol>\n<li>Check to see if the intake screen is clogged. If so, clean the inlet screen out.\u00a0 Pressure should restore immediately.<\/li>\n<li>If you have an inline screen with a clear top look for bubbles in the screen compartment. IF there are a lot of bubbles present, the air may be breaking the centrifugal action of the pump.\n<ol>\n<li>Is there an air stone or packed column discharging air bubbles where they can be drawn in to the pump?<\/li>\n<li>Check the seals on all threaded PVC pipe fittings on the suction side of the pump. Turn off the pump and let the filter backpressure the line.\u00a0 A small water leak will indicate a large air leak.<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<\/li>\n<\/ol>\n<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li>Check the very end of the inlet line for a vortex. Is water spinning and sucking air?\u00a0\u00a0 Raise the water level or break the vortex.<\/li>\n<\/ul>\n<ol>\n<li>IF you don\u2019t have an inlet screen protecting the pump: Remove the propeller housing from you pump and check for debris in the centrifugal chamber.\u00a0\u00a0 You will find it typically jammed across the outlet port.<\/li>\n<li>Remove the propeller housing on your pump and check the impeller for a broken blade or a loose set screw.<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<h4><strong>The unit continually \u201cburps\u201d air through the bed \u2026.unit never backwashes.<\/strong><\/h4>\n<p>Air passing through the bead bed during the filtration stage or just prior to backwashing indicates a backwashing issue.<\/p>\n<ol>\n<li>The trigger is clogged. This condition occurs most often when a unit is just set up or subject to heavy organic loading.\u00a0 Basically a clump of beads has jammed in the trigger preventing air release.\n<ol>\n<li>Try tapping the trigger on the inlet end (the low end) with a rubber mallet. This will normally vibrate the clump free.<\/li>\n<li>Try tapping the trigger on the discharge end (the high end) with a rubber mallet, the clog may be at this end.<\/li>\n<li>Try draining the filter about half way while the chamber is still filled with air. This will increase the pressure differential and allow the clump of beads to be pushed out.<\/li>\n<li>Remove the trigger and inspect for obstruction.<\/li>\n<\/ol>\n<\/li>\n<li>The charge chamber is leaking (the filter has be recently transported): Turn off the air supply to the charge chamber. If the bubbles continue, then you may have a leak. Pull the filtration head and screen.\u00a0\u00a0 Remove the beads.\u00a0 Fill the unit with water until the trigger out let is covered by about 12 inches of water.\u00a0 Fill the charge chamber and inspect for leaking bubbles.<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<h4><strong>The unit \u201cburps\u201d air through the bed before it backwashes.<\/strong><\/h4>\n<p>Delays in trigger firing are sometimes evidenced by a slow release of air through the trigger or under the HPPG cone.\u00a0 These delays undermined the backwashing strategy and should be corrected.<\/p>\n<ol>\n<li>If you are accelerating the wash sequence by dramatically increasing the rate of air input then reduce the rate of input. It takes several seconds for a trigger to respond to a change in air level in the charge chamber.\u00a0 This causes a lag time between filling the chamber and trigger release.\u00a0 If you put the air in too fast then the chamber will overflow air before the trigger can react.<\/li>\n<li>Your trigger could be loosely clogged. The clog produces a backpressure on the charge chamber, but slowly releases air.\u00a0 The air passing through the trigger clog, however, erodes the clog and the unit then backflushes after a few seconds. \u00a0\u00a0Try increasing the backflush frequency.\u00a0 This will loosen up the beads, knocking off excessive biofilm that is sinking them and cause them to move into the charge chamber where they cause problems. A partially clogged trigger can lead to a visible discharge of dirty water.<\/li>\n<li>The discharge end of your trigger maybe embedded in the bead bed. Beads cannot escape for the trigger and a transitional stream of bubbles results.\u00a0\u00a0 You have too many beads in the unit or the bed is eroding and piling beads on top of the trigger.\u00a0 Try reducing the water flow to the unit.<\/li>\n<li>Unit maybe poorly leveled. If the unit is poorly leveled then some air may release just moments before the trigger.\u00a0 Normally is seen only when a marginally leveled unit is coupled with a low backwash interval.\u00a0 Try leveling the unit by raising the side opposite the trigger.<\/li>\n<li>The trigger may be set to low (is this a new filter?). Try raising the unit on the trigger side and test firing.\u00a0 Call AST; highly unlikely, as all units are test fired before shipping.<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<h4><strong>The beads seem to be fluidizing.<\/strong><\/h4>\n<ol>\n<li>The High Profile <em>PolyGeyser<sup>\u00ae<\/sup><\/em> Bead Filter Models HPPG-10, HPPG-20, HPPG-30, HPPG-40, and HPPG-50 are designed with specific peak flow rates. If you exceed this flow rate, you can cause the beads to fluidize.\u00a0 When beads are fluidizing, they do not capture solids. To correct this problem, simply reduce the flow through the filter.<\/li>\n<li>Or, the inlet diffuser might be broken or be rotated out of the proper vertical position.\u00a0 \u00a0\u00a0Lower the bead bed by draining and check to see if the top of the inlet diffuser opens vertically.\u00a0 The diffuser should be securely anchored to the sidewall on both ends.\u00a0 If not call or email AST for assistance.<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<h4><strong>The sludge coming out of my HPPG stinks like rotten eggs.<\/strong><\/h4>\n<p>This is part of the price paid for water conservation.\u00a0 Organically rich sludge decaying in the absence of oxygen will smell like rotten eggs as sulfur is reduced. This is a transitional problem.\u00a0 Once the sludge is exposed to oxygen, the smell will disappear.<\/p>\n<ol>\n<li>Try increasing your backflush frequency.<\/li>\n<li>Discharge your sludge though a hose that will prevent exposure to the air.<\/li>\n<li>Take sludge out of the HPPG more often.<\/li>\n<\/ol>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p><div class=\"et_pb_module lwp_divi_breadcrumbs lwp_divi_breadcrumbs_0\">\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<div class=\"et_pb_module_inner\">\n\t\t\t\t\t<div class=\"lwp-breadcrumbs\"> <span class=\"before\"><\/span> <span vocab=\"https:\/\/schema.org\/\" typeof=\"BreadcrumbList\"><span property=\"itemListElement\" typeof=\"ListItem\"><a property=\"item\" typeof=\"WebPage\" href=\"https:\/\/astfilters.com\/aquatic-systems\/\" class=\"home\"><span property=\"name\">Home<\/span><\/a><meta property=\"position\" content=\"1\"><\/span> <span class=\"separator et-pb-icon\">E<\/span> <\/span><\/div>\n\t\t\t\t<\/div>\n\t\t\t<\/div>High Profile PolyGeyser FAQ &amp; Troubleshooting Dirty water comes out of my filter after a backwash. The\u00a0HPPG was specifically designed to minimize this issue. You are manually activating the backwash: The HPPG unit was designed with the presumption that backwash intervals would be short. Automate the unit and increase the backwash frequency You have the unit on an extended backwash interval: Increase the backwash frequency and keep the bed clean of debris. If your unit takes more than 5 seconds for air discharge: The trigger is blocked or partially blocked. You have a dysfunctional trigger and the unit is not dropping properly. See the section on the air \u201cburps\u201d. If your unit washes quickly (&lt;5 seconds) but fails to drop (look through the port hole), you may be flooding the filter with excessive flow during the wash. Check if your water pump sized properly for the HPPG model. \u00a0 The flow coming out of my HPPG is dramatically reduced.\u00a0 Check your pressure gauge on the pump side of the filter. If it low, you have a water pump issue. If it is high, you have a backwash problem. If your pump pressure [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":3242,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","inline_featured_image":false,"footnotes":""},"class_list":["post-3211","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>High Profile PolyGeyser FAQ &amp; Troubleshooting - AST Bead Filters<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/astfilters.com\/aquatic-systems\/support\/high-profile-polygeyser-filter-resources\/high-profile-polygeyser-faq-troubleshooting\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"High Profile PolyGeyser FAQ &amp; Troubleshooting - AST Bead Filters\" \/>\n<meta property=\"og:description\" content=\"High Profile PolyGeyser FAQ &amp; Troubleshooting Dirty water comes out of my filter after a backwash. The\u00a0HPPG was specifically designed to minimize this issue. You are manually activating the backwash: The HPPG unit was designed with the presumption that backwash intervals would be short. Automate the unit and increase the backwash frequency You have the unit on an extended backwash interval: Increase the backwash frequency and keep the bed clean of debris. If your unit takes more than 5 seconds for air discharge: The trigger is blocked or partially blocked. You have a dysfunctional trigger and the unit is not dropping properly. See the section on the air \u201cburps\u201d. If your unit washes quickly (&lt;5 seconds) but fails to drop (look through the port hole), you may be flooding the filter with excessive flow during the wash. Check if your water pump sized properly for the HPPG model. \u00a0 The flow coming out of my HPPG is dramatically reduced.\u00a0 Check your pressure gauge on the pump side of the filter. If it low, you have a water pump issue. If it is high, you have a backwash problem. If your pump pressure [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/astfilters.com\/aquatic-systems\/support\/high-profile-polygeyser-filter-resources\/high-profile-polygeyser-faq-troubleshooting\/\" \/>\n<meta property=\"og:site_name\" content=\"Aquatic Systems\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-08T17:25:19+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/astfilters.com\\\/aquatic-systems\\\/support\\\/high-profile-polygeyser-filter-resources\\\/high-profile-polygeyser-faq-troubleshooting\\\/\",\"url\":\"https:\\\/\\\/astfilters.com\\\/aquatic-systems\\\/support\\\/high-profile-polygeyser-filter-resources\\\/high-profile-polygeyser-faq-troubleshooting\\\/\",\"name\":\"High Profile PolyGeyser FAQ & Troubleshooting - AST Bead Filters\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/astfilters.com\\\/aquatic-systems\\\/#website\"},\"datePublished\":\"2016-08-26T16:31:04+00:00\",\"dateModified\":\"2024-02-08T17:25:19+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/astfilters.com\\\/aquatic-systems\\\/support\\\/high-profile-polygeyser-filter-resources\\\/high-profile-polygeyser-faq-troubleshooting\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/astfilters.com\\\/aquatic-systems\\\/support\\\/high-profile-polygeyser-filter-resources\\\/high-profile-polygeyser-faq-troubleshooting\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/astfilters.com\\\/aquatic-systems\\\/support\\\/high-profile-polygeyser-filter-resources\\\/high-profile-polygeyser-faq-troubleshooting\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/astfilters.com\\\/aquatic-systems\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Support Overview\",\"item\":\"https:\\\/\\\/astfilters.com\\\/aquatic-systems\\\/support\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"High Profile PolyGeyser\u00ae Filter Resources\",\"item\":\"https:\\\/\\\/astfilters.com\\\/aquatic-systems\\\/support\\\/high-profile-polygeyser-filter-resources\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"High Profile PolyGeyser FAQ &#038; Troubleshooting\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/astfilters.com\\\/aquatic-systems\\\/#website\",\"url\":\"https:\\\/\\\/astfilters.com\\\/aquatic-systems\\\/\",\"name\":\"Aquatic Systems\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/astfilters.com\\\/aquatic-systems\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"High Profile PolyGeyser FAQ & Troubleshooting - AST Bead Filters","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/astfilters.com\/aquatic-systems\/support\/high-profile-polygeyser-filter-resources\/high-profile-polygeyser-faq-troubleshooting\/","og_locale":"en_US","og_type":"article","og_title":"High Profile PolyGeyser FAQ & Troubleshooting - AST Bead Filters","og_description":"High Profile PolyGeyser FAQ &amp; Troubleshooting Dirty water comes out of my filter after a backwash. The\u00a0HPPG was specifically designed to minimize this issue. You are manually activating the backwash: The HPPG unit was designed with the presumption that backwash intervals would be short. Automate the unit and increase the backwash frequency You have the unit on an extended backwash interval: Increase the backwash frequency and keep the bed clean of debris. If your unit takes more than 5 seconds for air discharge: The trigger is blocked or partially blocked. You have a dysfunctional trigger and the unit is not dropping properly. See the section on the air \u201cburps\u201d. If your unit washes quickly (&lt;5 seconds) but fails to drop (look through the port hole), you may be flooding the filter with excessive flow during the wash. Check if your water pump sized properly for the HPPG model. \u00a0 The flow coming out of my HPPG is dramatically reduced.\u00a0 Check your pressure gauge on the pump side of the filter. If it low, you have a water pump issue. If it is high, you have a backwash problem. If your pump pressure [&hellip;]","og_url":"https:\/\/astfilters.com\/aquatic-systems\/support\/high-profile-polygeyser-filter-resources\/high-profile-polygeyser-faq-troubleshooting\/","og_site_name":"Aquatic Systems","article_modified_time":"2024-02-08T17:25:19+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/astfilters.com\/aquatic-systems\/support\/high-profile-polygeyser-filter-resources\/high-profile-polygeyser-faq-troubleshooting\/","url":"https:\/\/astfilters.com\/aquatic-systems\/support\/high-profile-polygeyser-filter-resources\/high-profile-polygeyser-faq-troubleshooting\/","name":"High Profile PolyGeyser FAQ & Troubleshooting - AST Bead Filters","isPartOf":{"@id":"https:\/\/astfilters.com\/aquatic-systems\/#website"},"datePublished":"2016-08-26T16:31:04+00:00","dateModified":"2024-02-08T17:25:19+00:00","breadcrumb":{"@id":"https:\/\/astfilters.com\/aquatic-systems\/support\/high-profile-polygeyser-filter-resources\/high-profile-polygeyser-faq-troubleshooting\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/astfilters.com\/aquatic-systems\/support\/high-profile-polygeyser-filter-resources\/high-profile-polygeyser-faq-troubleshooting\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/astfilters.com\/aquatic-systems\/support\/high-profile-polygeyser-filter-resources\/high-profile-polygeyser-faq-troubleshooting\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/astfilters.com\/aquatic-systems\/"},{"@type":"ListItem","position":2,"name":"Support Overview","item":"https:\/\/astfilters.com\/aquatic-systems\/support\/"},{"@type":"ListItem","position":3,"name":"High Profile PolyGeyser\u00ae Filter Resources","item":"https:\/\/astfilters.com\/aquatic-systems\/support\/high-profile-polygeyser-filter-resources\/"},{"@type":"ListItem","position":4,"name":"High Profile PolyGeyser FAQ &#038; Troubleshooting"}]},{"@type":"WebSite","@id":"https:\/\/astfilters.com\/aquatic-systems\/#website","url":"https:\/\/astfilters.com\/aquatic-systems\/","name":"Aquatic Systems","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/astfilters.com\/aquatic-systems\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/astfilters.com\/aquatic-systems\/wp-json\/wp\/v2\/pages\/3211","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/astfilters.com\/aquatic-systems\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/astfilters.com\/aquatic-systems\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/astfilters.com\/aquatic-systems\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/astfilters.com\/aquatic-systems\/wp-json\/wp\/v2\/comments?post=3211"}],"version-history":[{"count":0,"href":"https:\/\/astfilters.com\/aquatic-systems\/wp-json\/wp\/v2\/pages\/3211\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/astfilters.com\/aquatic-systems\/wp-json\/wp\/v2\/pages\/3242"}],"wp:attachment":[{"href":"https:\/\/astfilters.com\/aquatic-systems\/wp-json\/wp\/v2\/media?parent=3211"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}